Settings for registers of Ambient 20 Click driver.
More...
Settings for registers of Ambient 20 Click driver.
◆ AMBIENT20_100mS_MODE
#define AMBIENT20_100mS_MODE 0x00 |
◆ AMBIENT20_55mS_MODE
#define AMBIENT20_55mS_MODE 0x01 |
◆ AMBIENT20_DATA0_CONVERSION_COEF
#define AMBIENT20_DATA0_CONVERSION_COEF 0.169491525 |
Ambient 20 data conversion coefficients.
Specified setting for data conversion of Ambient 20 Click driver. These coefficients are gathered from the datasheet of the device by dividing the typical data count value by the lux value it represents.
◆ AMBIENT20_DATA1_CONVERSION_COEF
#define AMBIENT20_DATA1_CONVERSION_COEF 0.689655172 |
◆ AMBIENT20_DEVICE_ADDRESS
#define AMBIENT20_DEVICE_ADDRESS 0x38 |
Ambient 20 device address setting.
Specified setting for device slave address selection of Ambient 20 Click driver.
◆ AMBIENT20_DISABLE
#define AMBIENT20_DISABLE 0x00 |
◆ AMBIENT20_ENABLE
#define AMBIENT20_ENABLE 0x01 |
◆ AMBIENT20_GAIN_X1
#define AMBIENT20_GAIN_X1 0x02 |
Ambient 20 description setting.
Specified setting for description of Ambient 20 Click driver.
◆ AMBIENT20_GAIN_X256
#define AMBIENT20_GAIN_X256 0x0C |
◆ AMBIENT20_GAIN_X32
#define AMBIENT20_GAIN_X32 0x0A |
◆ AMBIENT20_MANUFACTURER_ID
#define AMBIENT20_MANUFACTURER_ID 0xE0 |
◆ AMBIENT20_PART_ID
#define AMBIENT20_PART_ID 0x12 |
◆ AMBIENT20_PART_ID_MASK
#define AMBIENT20_PART_ID_MASK 0x3F |
◆ AMBIENT20_VALID_MASK
#define AMBIENT20_VALID_MASK 0x80 |