ambient7 2.0.0.0
Ambient 7 Click Driver

API for configuring and manipulating Ambient 7 Click driver. More...

Topics

 Ambient 7 MikroBUS Map
 MikroBUS pin mapping of Ambient 7 Click driver.
 

Functions

void ambient7_cfg_setup (ambient7_cfg_t *cfg)
 Ambient 7 configuration object setup function.
 
err_t ambient7_init (ambient7_t *ctx, ambient7_cfg_t *cfg)
 Ambient 7 initialization function.
 
err_t ambient7_read_an_pin_value (ambient7_t *ctx, uint16_t *data_out)
 Ambient 7 read AN pin value function.
 
err_t ambient7_read_an_pin_voltage (ambient7_t *ctx, float *data_out)
 Ambient 7 read AN pin voltage level function.
 

Detailed Description

API for configuring and manipulating Ambient 7 Click driver.

Any initialization code needed for MCU to function properly. Do not remove this line or clock might not be set correctly.

Function Documentation

◆ ambient7_cfg_setup()

void ambient7_cfg_setup ( ambient7_cfg_t * cfg)

Ambient 7 configuration object setup function.

This function initializes click configuration structure to initial values.

Parameters
[out]cfg: Click configuration structure. See ambient7_cfg_t object definition for detailed explanation.
Returns
Nothing.
Note
The all used pins will be set to unconnected state.

◆ ambient7_init()

err_t ambient7_init ( ambient7_t * ctx,
ambient7_cfg_t * cfg )

Ambient 7 initialization function.

This function initializes all necessary pins and peripherals used for this click board.

Parameters
[out]ctx: Click context object. See ambient7_t object definition for detailed explanation.
[in]cfg: Click configuration structure. See ambient7_cfg_t object definition for detailed explanation.
Returns
  • 0 - Success,
  • -1 - Error. See #err_t definition for detailed explanation.
Note
None.

◆ ambient7_read_an_pin_value()

err_t ambient7_read_an_pin_value ( ambient7_t * ctx,
uint16_t * data_out )

Ambient 7 read AN pin value function.

This function reads results of AD conversion of the AN pin.

Parameters
[in]ctx: Click context object. See ambient7_t object definition for detailed explanation.
[out]data_out: Output ADC result.
Returns
  • 0 - Success,
  • -1 - Error. See #err_t definition for detailed explanation.
Note
None.

◆ ambient7_read_an_pin_voltage()

err_t ambient7_read_an_pin_voltage ( ambient7_t * ctx,
float * data_out )

Ambient 7 read AN pin voltage level function.

This function reads results of AD conversion of the AN pin and converts them to proportional voltage level.

Parameters
[in]ctx: Click context object. See ambient7_t object definition for detailed explanation.
[out]data_out: Output voltage level of the analog pin [V].
Returns
  • 0 - Success,
  • -1 - Error. See #err_t definition for detailed explanation.
Note
The conversion to voltage depends on the entered configuration of the ADC (resolution, reference voltage).