environment2 2.0.0.0

Macros

#define ENVIRONMENT2_SGP40_CMD_MEASURE_RAW   0x260F
 Environment 2 SGP40 description commands.
 
#define ENVIRONMENT2_SGP40_CMD_MEASURE_TEST   0x280E
 
#define ENVIRONMENT2_SGP40_CMD_HEATER_OFF   0x3615
 
#define ENVIRONMENT2_SGP40_CMD_SOFT_RESET   0x0006
 
#define ENVIRONMENT2_SHT40_CMD_MEASURE_T_RH_HIGH_PRECISION   0xFD
 Environment 2 SHT40 description commands.
 
#define ENVIRONMENT2_SHT40_CMD_MEASURE_T_RH_MEDIUM_PRECISION   0xF6
 
#define ENVIRONMENT2_SHT40_CMD_MEASURE_T_RH_LOWEST_PRECISION   0xE0
 
#define ENVIRONMENT2_SHT40_CMD_READ_SERIAL   0x89
 
#define ENVIRONMENT2_SHT40_CMD_SOFT_RESET   0x94
 
#define ENVIRONMENT2_SHT40_CMD_ACTIVATE_HIGHEST_HEATER_1SEC   0x39
 
#define ENVIRONMENT2_SHT40_CMD_ACTIVATE_HIGHEST_HEATER_0_1SEC   0x32
 
#define ENVIRONMENT2_SHT40_CMD_ACTIVATE_MEDIUM_HEATER_1SEC   0x2F
 
#define ENVIRONMENT2_SHT40_CMD_ACTIVATE_MEDIUM_HEATER_0_1SEC   0x24
 
#define ENVIRONMENT2_SHT40_CMD_ACTIVATE_LOWEST_HEATER_1SEC   0x1E
 
#define ENVIRONMENT2_SHT40_CMD_ACTIVATE_LOWEST_HEATER_0_1SEC   0x15
 

Detailed Description

Macro Definition Documentation

◆ ENVIRONMENT2_SGP40_CMD_HEATER_OFF

#define ENVIRONMENT2_SGP40_CMD_HEATER_OFF   0x3615

◆ ENVIRONMENT2_SGP40_CMD_MEASURE_RAW

#define ENVIRONMENT2_SGP40_CMD_MEASURE_RAW   0x260F

Environment 2 SGP40 description commands.

Specified SGP40 commands for description of Environment 2 Click driver.

◆ ENVIRONMENT2_SGP40_CMD_MEASURE_TEST

#define ENVIRONMENT2_SGP40_CMD_MEASURE_TEST   0x280E

◆ ENVIRONMENT2_SGP40_CMD_SOFT_RESET

#define ENVIRONMENT2_SGP40_CMD_SOFT_RESET   0x0006

◆ ENVIRONMENT2_SHT40_CMD_ACTIVATE_HIGHEST_HEATER_0_1SEC

#define ENVIRONMENT2_SHT40_CMD_ACTIVATE_HIGHEST_HEATER_0_1SEC   0x32

◆ ENVIRONMENT2_SHT40_CMD_ACTIVATE_HIGHEST_HEATER_1SEC

#define ENVIRONMENT2_SHT40_CMD_ACTIVATE_HIGHEST_HEATER_1SEC   0x39

◆ ENVIRONMENT2_SHT40_CMD_ACTIVATE_LOWEST_HEATER_0_1SEC

#define ENVIRONMENT2_SHT40_CMD_ACTIVATE_LOWEST_HEATER_0_1SEC   0x15

◆ ENVIRONMENT2_SHT40_CMD_ACTIVATE_LOWEST_HEATER_1SEC

#define ENVIRONMENT2_SHT40_CMD_ACTIVATE_LOWEST_HEATER_1SEC   0x1E

◆ ENVIRONMENT2_SHT40_CMD_ACTIVATE_MEDIUM_HEATER_0_1SEC

#define ENVIRONMENT2_SHT40_CMD_ACTIVATE_MEDIUM_HEATER_0_1SEC   0x24

◆ ENVIRONMENT2_SHT40_CMD_ACTIVATE_MEDIUM_HEATER_1SEC

#define ENVIRONMENT2_SHT40_CMD_ACTIVATE_MEDIUM_HEATER_1SEC   0x2F

◆ ENVIRONMENT2_SHT40_CMD_MEASURE_T_RH_HIGH_PRECISION

#define ENVIRONMENT2_SHT40_CMD_MEASURE_T_RH_HIGH_PRECISION   0xFD

Environment 2 SHT40 description commands.

Specified SHT40 commands for description of Environment 2 Click driver.

◆ ENVIRONMENT2_SHT40_CMD_MEASURE_T_RH_LOWEST_PRECISION

#define ENVIRONMENT2_SHT40_CMD_MEASURE_T_RH_LOWEST_PRECISION   0xE0

◆ ENVIRONMENT2_SHT40_CMD_MEASURE_T_RH_MEDIUM_PRECISION

#define ENVIRONMENT2_SHT40_CMD_MEASURE_T_RH_MEDIUM_PRECISION   0xF6

◆ ENVIRONMENT2_SHT40_CMD_READ_SERIAL

#define ENVIRONMENT2_SHT40_CMD_READ_SERIAL   0x89

◆ ENVIRONMENT2_SHT40_CMD_SOFT_RESET

#define ENVIRONMENT2_SHT40_CMD_SOFT_RESET   0x94