thermo18 2.0.0.0
|
Thermo18 Click example. More...
Functions | |
void | application_init (void) |
void | application_task (void) |
int | main (void) |
Thermo18 Click example.
The example application showcases ability of device to read temperature and detect and assert interrupt on undertemperature or overtemperature thresholds.
The demo application is composed of two sections :
Initialization of communication modules and interrupt pin. Reads device ID to check comunication. Then resets device, and sets undertemperature and overtemperature thresholds on 24 and 30 degrees Celsius. In the end enables OneShot temperature conversion.
Checks status to see if the temperature conversion is finished. When it's finished reads and logs calculated temperature data. Then checks if status is asserted for threshold detection, and logs if detected. In the end re-enables OneShot conversion.
void application_init | ( | void | ) |
< Logger config object.
< Click config object.
Logger initialization. Default baud rate: 115200 Default log level: LOG_LEVEL_DEBUG
void application_task | ( | void | ) |
int main | ( | void | ) |