alcohol 2.0.0.0
Main Page

Alcohol click

Alcohol click has a high sensitivity to alcohol and it can be used to detect alcohol in concentrations from 0.04 to 4mg/l.

Alcohol click carries an MQ-3 Semiconductor sensor for alcohol. The click is designed to run on a 5V power supply only. It communicates with the target microcontroller through the AN pin on the mikroBUS™ line.

click Product page


Click library

  • Author : Jelena Milosavljevic
  • Date : Jun 2021.
  • Type : ADC type

Software Support

We provide a library for the Alcohol Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

‍This library contains API for Alcohol Click driver.

Standard key functions :

Example key functions :

  • alcohol_read_an_pin_value This function reads results of AD conversion of the AN pin.
    err_t alcohol_read_an_pin_value ( alcohol_t *ctx, uint16_t *data_out );
    err_t alcohol_read_an_pin_value(alcohol_t *ctx, uint16_t *data_out)
    Alcohol read AN pin value function.
  • alcohol_read_an_pin_voltage This function reads results of AD conversion of the AN pin and converts them to proportional voltage level.
    err_t alcohol_read_an_pin_voltage ( alcohol_t *ctx, float *data_out );
    err_t alcohol_read_an_pin_voltage(alcohol_t *ctx, float *data_out)
    Alcohol read AN pin voltage level function.

Example Description

‍The demo application shows the reading of the adc values given by the sensors.

The demo application is composed of two sections :

Application Init

‍Configuring clicks and log objects.

void application_init ( void ) {
log_cfg_t log_cfg;
alcohol_cfg_t alcohol_cfg;
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
alcohol_cfg_setup( &alcohol_cfg );
ALCOHOL_MAP_MIKROBUS( alcohol_cfg, MIKROBUS_1 );
if ( alcohol_init( &alcohol, &alcohol_cfg ) == ADC_ERROR ) {
log_error( &logger, " Application Init Error. " );
log_info( &logger, " Please, run program again... " );
for ( ; ; );
}
log_info( &logger, " Application Task " );
}
#define ALCOHOL_MAP_MIKROBUS(cfg, mikrobus)
MikroBUS pin mapping.
Definition alcohol.h:72
void application_init(void)
Definition main.c:28

Application Task

‍Reads the adc value and prints in two forms (DEC and HEX).

void application_task ( void ) {
uint16_t alcohol_an_value = 0;
if ( alcohol_read_an_pin_value ( &alcohol, &alcohol_an_value ) != ADC_ERROR ) {
log_printf( &logger, " ADC Value : %u\r\n", alcohol_an_value );
}
float alcohol_an_voltage = 0;
if ( alcohol_read_an_pin_voltage ( &alcohol, &alcohol_an_voltage ) != ADC_ERROR ) {
log_printf( &logger, " AN Voltage : %.3f[V]\r\n\n", alcohol_an_voltage );
}
Delay_ms ( 1000 );
}
void application_task(void)
Definition main.c:59

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Alcohol

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.