TempHum 14 click
Temp & Hum 14 Click is a compact add-on board that contains one of the smallest and most accurate humidity and temperature sensors on the market. This board features the HTU31D, a highly accurate digital relative humidity sensor with temperature output from TE Connectivity. With power consumption down to 3.78μW and accuracy of ±2RH and ±0.2°C, this Click board™ provides fast response time, precision measurement, low hysteresis, and sustained performance even when exposed to extreme temperature up to 125°C and humidity environments.
click Product page
Click library
- Author : Stefan Ilic
- Date : Jul 2021.
- Type : I2C type
Software Support
We provide a library for the TempHum14 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.
Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.
Library Description
This library contains API for TempHum14 Click driver.
Standard key functions :
temphum14_cfg_setup
Config Object Initialization function.
void temphum14_cfg_setup(temphum14_cfg_t *cfg)
Temp Hum 14 configuration object setup function.
Temp Hum 14 Click configuration object.
Definition temphum14.h:186
temphum14_init
Initialization function.
err_t temphum14_init(temphum14_t *ctx, temphum14_cfg_t *cfg)
Temp Hum 14 initialization function.
Temp Hum 14 Click context object.
Definition temphum14.h:169
Example key functions :
temphum14_set_conversion
The function set conversion a single temperature and humidity conversion and select data resolution to the HTU31D RH/T SENSOR IC Digital Relative Humidity sensor with Temperature output on the Temp-Hum 14 click board.
void temphum14_set_conversion(temphum14_t *ctx, uint8_t hum_osr, uint8_t temp_osr)
Set conversion function.
temphum14_read_t_and_rh
The function read temperature and humidity data of the HTU31D RH/T SENSOR IC Digital Relative Humidity sensor with Temperature output on the Temp-Hum 14 click board.
void temphum14_read_t_and_rh(temphum14_t *ctx, uint8_t *p_rx_data)
Read temperature and humidity data function.
temphum14_get_temp_and_hum
The function get temperature and humidity value of the HTU31D RH/T SENSOR IC Digital Relative Humidity sensor with Temperature output on the Temp-Hum 14 click board.
void temphum14_get_temp_and_hum(temphum14_t *ctx, float *temp, float *hum)
Get temperature and humidity data function.
Example Description
This is an example that demonstrates the use of the Temp-Hum 14 Click board. Temp-Hum 14 Click board can be used to measure temperature and relative humidity. All data logs write on USB uart changes every 3 sec.
The demo application is composed of two sections :
Application Init
Initialization driver enables I2C, and hardware reset the device and read the serial number.
log_cfg_t log_cfg;
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_printf( &logger, "-----------------------------\r\n" );
log_info( &logger, " Application Init " );
log_printf( &logger, "-----------------------------\r\n" );
if ( I2C_MASTER_ERROR == init_flag ) {
log_error( &logger, " Application Init Error. " );
log_info( &logger, " Please, run program again... " );
for ( ; ; );
}
Delay_ms ( 100 );
log_printf( &logger, "-----------------------------\r\n" );
log_printf( &logger, " Hardware Reset \r\n" );
Delay_ms ( 100 );
log_printf( &logger, "-----------------------------\r\n" );
log_printf( &logger,
" Serial Number : %lu \r\n",
ser_numb );
log_printf( &logger, "-----------------------------\r\n" );
log_printf( &logger, " Software Reset \r\n" );
Delay_ms ( 100 );
Delay_ms ( 10 );
Delay_ms ( 100 );
log_info( &logger, " Application Task " );
log_printf( &logger, "-----------------------------\r\n" );
}
#define TEMPHUM14_MAP_MIKROBUS(cfg, mikrobus)
MikroBUS pin mapping.
Definition temphum14.h:156
uint32_t temphum14_get_serial_number(temphum14_t *ctx)
Get serial number function.
void temphum14_hw_reset(temphum14_t *ctx)
HW reset function.
void temphum14_get_diagnostic(temphum14_t *ctx, temphum14_diagn_t *diag_data)
Get diagnostic status function.
void temphum14_soft_reset(temphum14_t *ctx)
Soft reset function.
void application_init(void)
Definition main.c:86
void display_diagnostic(void)
Definition main.c:35
uint32_t ser_numb
Definition main.c:33
Application Task
Reading temperature and humidity, and loging it on the USB uart.
Delay_ms ( 10 );
Delay_ms ( 10 );
log_printf( &logger, " Temperature : %.2f C \r\n", temperature );
log_printf( &logger, " Humidity : %.2f %% \r\n", humidity );
log_printf( &logger, "-----------------------------\r\n" );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
}
#define TEMPHUM14_CONVERSION_HUM_OSR_0_020
Definition temphum14.h:102
#define TEMPHUM14_CONVERSION_TEMP_0_040
Definition temphum14.h:106
void application_task(void)
Definition main.c:139
The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.
Other Mikroe Libraries used in the example:
- MikroSDK.Board
- MikroSDK.Log
- Click.TempHum14
Additional notes and informations
Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.