temphum22 2.1.0.0
Main Page

TempHum 22 click

‍Temp&Hum 22 Click is a compact add-on board representing temperature and humidity sensing solution. This board features the SHT41A, a 4th generation automotive-grade relative humidity and temperature sensor from Sensirion. The SHT41A is characterized by its high accuracy (±2% RH and ±0.3°C over a wide operating temperature range) and high resolution providing 16-bit data to the host controller with a configurable I2C interface. Also, it is designed for reliable operation in harsh conditions such as condensing environments.

click Product page


Click library

  • Author : Stefan Filipovic
  • Date : Aug 2022.
  • Type : I2C type

Software Support

We provide a library for the TempHum 22 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

‍This library contains API for TempHum 22 Click driver.

Standard key functions :

Example key functions :

Example Description

‍This example demonstrates the use of Temp & Hum 22 click board by reading the temperature and humidity data.

The demo application is composed of two sections :

Application Init

‍Initializes the driver, performs the sensor software reset and then reads and displays the sensor unique serial number.

void application_init ( void )
{
log_cfg_t log_cfg;
temphum22_cfg_t temphum22_cfg;
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
temphum22_cfg_setup( &temphum22_cfg );
TEMPHUM22_MAP_MIKROBUS( temphum22_cfg, MIKROBUS_1 );
if ( I2C_MASTER_ERROR == temphum22_init( &temphum22, &temphum22_cfg ) )
{
log_error( &logger, " Communication init." );
for ( ; ; );
}
if ( TEMPHUM22_OK == temphum22_soft_reset ( &temphum22 ) )
{
log_printf ( &logger, " Software reset\r\n" );
}
Delay_1sec ( );
uint32_t serial_num;
if ( TEMPHUM22_OK == temphum22_read_serial_num ( &temphum22, &serial_num ) )
{
log_printf ( &logger, " Serial number: 0x%.8LX\r\n", serial_num );
}
log_info( &logger, " Application Task " );
}
#define TEMPHUM22_MAP_MIKROBUS(cfg, mikrobus)
MikroBUS pin mapping.
Definition temphum22.h:132
void application_init(void)
Definition main.c:30
@ TEMPHUM22_OK
Definition temphum22.h:173

Application Task

‍Reads the temperature (degC) and the relative humidity (RH) data and displays the results on the USB UART approximately once per second.

void application_task ( void )
{
float temperature, humidity;
if ( TEMPHUM22_OK == temphum22_read_measurement_high_precision ( &temphum22, &temperature, &humidity ) )
{
log_printf ( &logger, " Temperature: %.2f degC\r\n", temperature );
log_printf ( &logger, " Humidity: %.2f %%RH\r\n\n", humidity );
Delay_ms ( 1000 );
}
}
void application_task(void)
Definition main.c:72

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.TempHum22

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.