vreg 2.0.0.0
Main Page

VREG click

VReg click is a digitally controlled DC Voltage regulator in mikroBUS™ form factor.

click Product page


Click library

  • Author : MikroE Team
  • Date : Jun 2020.
  • Type : SPI type

Software Support

We provide a library for the Vreg Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.

Library Description

‍This library contains API for Vreg Click driver.

Standard key functions :

  • Config Object Initialization function.

    ‍void vreg_cfg_setup ( vreg_cfg_t *cfg );

    - Initialization function.

    ‍VREG_RETVAL vreg_init ( vreg_t *ctx, vreg_cfg_t *cfg );

    Example key functions :

  • Get ADC value function.

    ‍uint16_t vreg_get_adc ( vreg_t *ctx, uint8_t channel );

    - Set output voltage function. >void vreg_set_out_voltage ( vreg_t *ctx, uint16_t value_dac );
  • Set output voltage procentage function.

    ‍void vreg_set_output_voltage_procentage ( vreg_t *ctx, uint8_t value_dac_pct );

    Examples Description

‍This is an example that demonstrates the use of VREG click board.

The demo application is composed of two sections :

Application Init

‍Initializes driver and sets output voltage.

void application_init ( void )
{
log_cfg_t log_cfg;
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, "---- Application Init ----" );
// Click initialization.
vreg_cfg_setup( &cfg );
VREG_MAP_MIKROBUS( cfg, MIKROBUS_1 );
vreg_init( &vreg, &cfg );
log_printf( &logger, " Stop Measuring \r\n" );
Delay_1sec( );
log_printf( &logger, " Set Out Voltage \r\n" );
vreg_set_out_voltage( &vreg, 600 );
Delay_1sec( );
log_printf( &logger, " Start Measuring \r\n" );
Delay_1sec( );
}
#define VREG_MAP_MIKROBUS(cfg, mikrobus)
Definition vreg.h:68
void vreg_cfg_setup(vreg_cfg_t *cfg)
Config Object Initialization function.
void vreg_stop_measuring(vreg_t *ctx)
Stop the measuring function.
VREG_RETVAL vreg_init(vreg_t *ctx, vreg_cfg_t *cfg)
Initialization function.
void vreg_set_out_voltage(vreg_t *ctx, uint16_t value_dac)
Set output voltage function.
void vreg_start_measuring(vreg_t *ctx)
Start the measuring function.
void application_init(void)
Definition main.c:38
Click configuration structure definition.
Definition vreg.h:124

Application Task

‍Reads ADC data from all 3 channels, converts those values to voltage and displays the results on USB UART.

void application_task ( void )
{
ch_reg = vreg_get_adc( &vreg, VREG_CHANNEL_0 );
voltage = ch_reg / 182.0;
log_printf( &logger, " CH Reg : %.2f V\r\n", voltage );
Delay_10ms( );
ch_in = vreg_get_adc( &vreg, VREG_CHANNEL_2 );
voltage = ch_in / 182.0;
log_printf( &logger, " CH In : %.2f V\r\n", voltage );
Delay_10ms( );
ch_out = vreg_get_adc( &vreg, VREG_CHANNEL_1 );
voltage = ch_out / 182.0;
log_printf( &logger, " CH Out : %.2f V\r\n", voltage );
Delay_1sec( );
log_printf( &logger, " ---------------------- \r\n" );
}
#define VREG_CHANNEL_2
Definition vreg.h:89
#define VREG_CHANNEL_1
Definition vreg.h:88
#define VREG_CHANNEL_0
Definition vreg.h:87
uint16_t vreg_get_adc(vreg_t *ctx, uint8_t channel)
Get ADC value function.
void application_task(void)
Definition main.c:75

The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.

Other mikroE Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Vreg

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.