Water Detect 2 click

‍Water Detect 2 Click is a compact add-on board that can detect the presence/flow of a liquid in a clear tube. This board features the OPB350L250, a tube liquid sensor from TT Electronics. Water Detect 2 Click has multiple output states and can recognize fluid present, no fluid present, and no tube present. This sensor excepts 1/4” tubing (6.3mm) as an outside diameter of the clear tubes, regardless of the direction of the liquid’s flow.

click Product page


Click library

  • Author : Nenad Filipovic
  • Date : Jul 2023.
  • Type : GPIO type

Software Support

We provide a library for the Water Detect 2 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

‍This library contains API for Water Detect 2 Click driver.

Standard key functions :

Example key functions :

Example Description

‍This library contains API for Water Detect 2 Click driver. Water Detect 2 click is used for detecting water and other electroconductive liquids.

The demo application is composed of two sections :

Application Init

‍Initializes driver and performs the default configuration.

void application_init ( void )
{
log_cfg_t log_cfg;
waterdetect2_cfg_t waterdetect2_cfg;
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
waterdetect2_cfg_setup( &waterdetect2_cfg );
WATERDETECT2_MAP_MIKROBUS( waterdetect2_cfg, MIKROBUS_1 );
if ( DIGITAL_OUT_UNSUPPORTED_PIN == waterdetect2_init( &waterdetect2, &waterdetect2_cfg ) )
{
log_error( &logger, " Communication init." );
for ( ; ; );
}
waterdetect2_default_cfg( &waterdetect2 );
log_info( &logger, " Application Task " );
}
#define WATERDETECT2_MAP_MIKROBUS(cfg, mikrobus)
MikroBUS pin mapping.
Definition waterdetect2.h:85
void application_init(void)
Definition main.c:29

Application Task

‍Reads fluid presence status and determines if there is fluid presence or not.

void application_task ( void )
{
uint8_t fluid_status = waterdetect2_get_fluid_status( &waterdetect2 );
if ( fluid_status != fluid_status_old )
{
if ( WATERDETECT2_FLUID_DETECTED == fluid_status )
{
log_printf( &logger, " Fluid present! \r\n" );
}
else
{
log_printf( &logger, " No fluid present. \r\n" );
}
log_printf( &logger, "------------------- \r\n" );
fluid_status_old = fluid_status;
}
}
#define WATERDETECT2_FLUID_DETECTED
Definition waterdetect2.h:67
void application_task(void)
Definition main.c:60

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.WaterDetect2

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.