waterdetect3 2.1.0.0
Main Page

Water Detect 3 click

‍Water Detect 3 Click is a compact add-on board that detects water and other electroconductive liquids. This board features the MCP606, a micropower CMOS operational amplifier from Microchip. In the same package, the Water Detect 3 Click comes with a separate PCB with an electroconductive water detection area connected to a Click boardâ„¢ with wires.

click Product page


Click library

  • Author : Stefan Ilic
  • Date : Aug 2023.
  • Type : GPIO type

Software Support

We provide a library for the Water Detect 3 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

‍This library contains API for Water Detect 3 Click driver.

Standard key functions :

Example key functions :

Example Description

‍This example demonstrates the use of the Water Detect 3 Click board by detecting if water is present on the sensor part of the click.

The demo application is composed of two sections :

Application Init

‍Initializes the driver and configures hardware for the detection.

void application_init ( void )
{
log_cfg_t log_cfg;
waterdetect3_cfg_t waterdetect3_cfg;
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
waterdetect3_cfg_setup( &waterdetect3_cfg );
WATERDETECT3_MAP_MIKROBUS( waterdetect3_cfg, MIKROBUS_1 );
if ( DIGITAL_OUT_UNSUPPORTED_PIN == waterdetect3_init( &waterdetect3, &waterdetect3_cfg ) )
{
log_error( &logger, " Communication init." );
for ( ; ; );
}
log_printf( &logger, " Turn potentiometer VR1 all the way to the right.\r\n" );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
log_printf( &logger, " Place a few drops of water onto the sensor.\r\n" );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
log_printf( &logger, " Turn potentiometer VR1 to the left until the detect LED turns off.\r\n" );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
while ( WATERDETECT3_PIN_STATE_HIGH == waterdetect3_get_int( &waterdetect3 ) );
log_printf( &logger, " Device is ready.\r\n" );
log_info( &logger, " Application Task " );
}
#define WATERDETECT3_MAP_MIKROBUS(cfg, mikrobus)
MikroBUS pin mapping.
Definition waterdetect3.h:86
#define WATERDETECT3_PIN_STATE_HIGH
Water Detect 3 description setting.
Definition waterdetect3.h:67
void application_init(void)
Definition main.c:28

Application Task

‍Detects if any water is present on the sensor part.

void application_task ( void )
{
{
log_printf( &logger, " Water detected.\r\n" );
Delay_ms ( 1000 );
}
}
void application_task(void)
Definition main.c:81

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.WaterDetect3

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.