adc13 2.0.0.0
Main Page

ADC 13 click

ADC 13 Click is a compact add-on board that contains a high-performance data converter. This board features the ADS1262, a 32-bit, high precision, 38-kSPS, analog-to-digital converter with programmable gain amplifier and voltage reference from Texas Instruments.

click Product page


Click library

  • Author : Stefan Filipovic
  • Date : Jun 2021.
  • Type : SPI type

Software Support

We provide a library for the ADC13 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

‍This library contains API for ADC13 Click driver.

Standard key functions :

  • adc13_cfg_setup Config Object Initialization function.
    void adc13_cfg_setup(adc13_cfg_t *cfg)
    ADC 13 configuration object setup function.
    ADC 13 Click configuration object.
    Definition adc13.h:573
  • adc13_init Initialization function.
    err_t adc13_init ( adc13_t *ctx, adc13_cfg_t *cfg );
    err_t adc13_init(adc13_t *ctx, adc13_cfg_t *cfg)
    ADC 13 initialization function.
    ADC 13 Click context object.
    Definition adc13.h:553
  • adc13_default_cfg Click Default Configuration function.
    err_t adc13_default_cfg ( adc13_t *ctx );
    err_t adc13_default_cfg(adc13_t *ctx)
    ADC 13 default configuration function.

Example key functions :

  • adc13_measure_voltage This function starts ADC conversation, reads RAW ADC data then calculates the voltage using the input vref for calculations.
    err_t adc13_measure_voltage ( adc13_t *ctx, float vref, float *voltage );
    err_t adc13_measure_voltage(adc13_t *ctx, float vref, float *voltage)
    ADC 13 measure voltage function.
  • adc13_measure_temperature This function measures the internal temperature in Celsius.
    err_t adc13_measure_temperature ( adc13_t *ctx, float *temperature );
    err_t adc13_measure_temperature(adc13_t *ctx, float *temperature)
    ADC 13 measure temperature function.
  • adc13_set_input_channel This function sets the ADC input positive and negative channels.
    err_t adc13_set_input_channel ( adc13_t *ctx, uint8_t pos, uint8_t neg );
    err_t adc13_set_input_channel(adc13_t *ctx, uint8_t pos, uint8_t neg)
    ADC 13 set input channel function.

Example Description

‍This example demonstrates the use of ADC 13 click board.

The demo application is composed of two sections :

Application Init

‍Initializes the driver and performs the click default configuration.

void application_init ( void )
{
log_cfg_t log_cfg;
adc13_cfg_t adc13_cfg;
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
adc13_cfg_setup( &adc13_cfg );
ADC13_MAP_MIKROBUS( adc13_cfg, MIKROBUS_1 );
err_t init_flag = adc13_init( &adc13, &adc13_cfg );
if ( SPI_MASTER_ERROR == init_flag )
{
log_error( &logger, " Application Init Error. " );
log_info( &logger, " Please, run program again... " );
for ( ; ; );
}
adc13_default_cfg ( &adc13 );
log_info( &logger, " Application Task " );
}
#define ADC13_MAP_MIKROBUS(cfg, mikrobus)
MikroBUS pin mapping.
Definition adc13.h:536
void application_init(void)
Definition main.c:32

Application Task

‍Reads the voltage between AIN0 and AIN1 channels, and the module internal temperature as well. All values are being displayed on the USB UART where you can track their changes.

void application_task ( void )
{
float voltage = 0;
float temperature = 0;
log_printf( &logger, " Voltage: %.3f V\r\n", voltage );
adc13_measure_temperature ( &adc13, &temperature );
log_printf( &logger, " Temperature: %.2f C\r\n", temperature );
log_printf( &logger, " ---------------------------\r\n" );
Delay_ms ( 500 );
}
#define ADC13_VREF_INTERNAL
Voltage reference.
Definition adc13.h:467
void application_task(void)
Definition main.c:67

Note

‍An internal 2.5V reference is set by default. If you want, you can change it using the adc13_set_voltage_reference function.

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.ADC13

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all MikroElektronika compilers, or any other terminal application of your choice, can be used to read the message.