eFuse 2 click
eFuse 2 Click is a compact add-on board that contains an integrated FET hot-swap device. This board features the TPS259631, a highly integrated circuit protection and power management solution from Texas Instruments. It provides multiple protection modes against overloads, short circuits, voltage surges, and excessive inrush current.
click Product page
Click library
- Author : Stefan Ilic
- Date : Aug 2021.
- Type : I2C type
Software Support
We provide a library for the eFuse2 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.
Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.
Library Description
This library contains API for eFuse2 Click driver.
Standard key functions :
efuse2_cfg_setup
Config Object Initialization function.
void efuse2_cfg_setup(efuse2_cfg_t *cfg)
eFuse 2 configuration object setup function.
eFuse 2 Click configuration object.
Definition efuse2.h:194
efuse2_init
Initialization function.
err_t efuse2_init(efuse2_t *ctx, efuse2_cfg_t *cfg)
eFuse 2 initialization function.
eFuse 2 Click context object.
Definition efuse2.h:173
efuse2_default_cfg
Click Default Configuration function.
err_t efuse2_default_cfg(efuse2_t *ctx)
eFuse 2 default configuration function.
Example key functions :
efuse2_set_operating_voltage
Set operating voltage function.
err_t efuse2_set_operating_voltage(efuse2_t *ctx, float voltage, float *min_voltage, float *max_voltage)
Set operating voltage function.
float max_voltage
Definition main.c:41
float min_voltage
Definition main.c:40
efuse2_set_current_limit
Set operating current function.
err_t efuse2_set_current_limit(efuse2_t *ctx, float current)
Set operating current function.
efuse2_get_fault
Get fault function.
uint8_t efuse2_get_fault(efuse2_t *ctx)
Get fault function.
Example Description
This is an example that demonstrate the use of the eFuse 2 click board.
The demo application is composed of two sections :
Application Init
Initialization driver enables - I2C,
AD5175: enable write, set the normal operating mode and operating current to the 1,2 A;
AD5241: set operating voltage to the 12,0 V; Display diagnostic states.
{
log_cfg_t log_cfg;
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
if ( I2C_MASTER_ERROR == init_flag )
{
log_error( &logger, " Application Init Error. " );
log_info( &logger, " Please, run program again... " );
for ( ; ; );
}
{
log_error( &logger, " Default configuration." );
for ( ; ; );
}
Delay_ms ( 100 );
log_printf( &logger, "-----------------------------\r\n" );
log_printf( &logger, " Set operating value: \r\n" );
log_printf( &logger, " Voltage: 12.0 V \r\n" );
Delay_ms ( 1000 );
log_printf( &logger, " Current: 1.2 A \r\n" );
log_printf( &logger, "-----------------------------\r\n" );
Delay_ms ( 1000 );
log_printf( &logger, " Turn ON Power Supply \r\n" );
log_printf( &logger, "-----------------------------\r\n" );
log_info( &logger, " Application Task " );
}
@ EFUSE2_ERROR
Definition efuse2.h:228
#define EFUSE2_MAP_MIKROBUS(cfg, mikrobus)
MikroBUS pin mapping.
Definition efuse2.h:159
void application_init(void)
Definition main.c:43
float op_voltage
Definition main.c:39
float op_current
Definition main.c:38
Application Task
eFuse 2 click board uses USB UART log to display operating voltage, OVLO, UVLO and current limit condition. This firmware provides the functions to set the operating voltage and current limiting conditions in order to provide the threshold of the fault conditions. When one of the fault conditions is met, the microcontroller is notified via INT pin which is checked by the app to initiate a shutdown mode. All data logs write on USB UART changes every 2000 milliseconds.
{
{
Delay_ms ( 1000 );
log_printf( &logger, " Shutdown Mode \r\n" );
log_printf( &logger, " Turn OFF the Power Supply \r\n" );
log_printf( &logger, " and restart the system \r\n" );
log_printf( &logger, "-----------------------------\r\n" );
for ( ; ; );
}
else
{
log_printf( &logger,
" Oper. Voltage : %.3f V \r\n",
op_voltage );
log_printf( &logger,
" Undervoltage : %.3f V \r\n",
min_voltage );
log_printf( &logger,
" Overvoltage : %.3f V \r\n",
max_voltage );
log_printf( &logger,
" Current Limit : %.3f A \r\n",
op_current );
log_printf( &logger, "-----------------------------\r\n" );
}
Delay_ms ( 1000 );
Delay_ms ( 1000 );
}
#define EFUSE2_AD5175_SHUTDOWN_MODE
Definition efuse2.h:75
#define EFUSE2_FAULT
eFuse 2 fault setting.
Definition efuse2.h:132
err_t efuse2_operating_mode(efuse2_t *ctx, uint8_t mode)
Set operating mode function.
void application_task(void)
Definition main.c:97
The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.
Other Mikroe Libraries used in the example:
- MikroSDK.Board
- MikroSDK.Log
- Click.eFuse2
Additional notes and informations
Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.