H-Bridge 6 click
H-Bridge 6 Click is a compact add-on board that contains a DC motor driver for automotive applications. This board features the VNHD7008AY, an H-bridge motor driver for automotive DC motor driving from STMicroelectronics. The VNHD7008AY, features an undervoltage shutdown, load current limitation, overload active power limitation, overtemperature shutdown, and more.
click Product page
Click library
- Author : Stefan Ilic
- Date : Jul 2021.
- Type : I2C type
Software Support
We provide a library for the HBridge6 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.
Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.
Library Description
This library contains API for HBridge6 Click driver.
Standard key functions :
hbridge6_cfg_setup
Config Object Initialization function.
void hbridge6_cfg_setup(hbridge6_cfg_t *cfg)
H-Bridge 6 configuration object setup function.
H-Bridge 6 Click configuration object.
Definition hbridge6.h:189
hbridge6_init
Initialization function.
err_t hbridge6_init(hbridge6_t *ctx, hbridge6_cfg_t *cfg)
H-Bridge 6 initialization function.
H-Bridge 6 Click context object.
Definition hbridge6.h:166
hbridge6_default_cfg
Click Default Configuration function.
err_t hbridge6_default_cfg(hbridge6_t *ctx)
H-Bridge 6 default configuration function.
Example key functions :
hbridge6_reset
HW reset function.
void hbridge6_reset(hbridge6_t *ctx)
HW reset function.
hbridge6_enable_diagnostic
Enable the diagnostic function.
void hbridge6_enable_diagnostic(hbridge6_t *ctx, uint8_t en_state)
Enable the diagnostic function.
hbridge6_set_direction
Adjust the direction function.
void hbridge6_set_direction(hbridge6_t *ctx, uint8_t direction)
Adjust the direction function.
Example Description
This is an example that demonstrates the use of H-Bridge 6 Click board.
The demo application is composed of two sections :
Application Init
Initialization driver enables - I2C, reset the device and set default configuration, initialization and configure the PWM, also write log.
log_cfg_t log_cfg;
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
if ( I2C_MASTER_ERROR == init_flag || PWM_ERROR == init_flag ) {
log_error( &logger, " Application Init Error. " );
log_info( &logger, " Please, run program again... " );
for ( ; ; );
}
log_printf( &logger, "-----------------------\r\n" );
log_printf( &logger, " Set default config. \r\n" );
log_printf( &logger, "-----------------------\r\n" );
Delay_ms ( 100 );
log_info( &logger, " Application Task " );
}
#define HBRIDGE6_MAP_MIKROBUS(cfg, mikrobus)
MikroBUS pin mapping.
Definition hbridge6.h:151
void application_init(void)
Definition main.c:32
Application Task
It shows moving in the clockwise direction of rotation and moving in the counterclockwise direction of rotation from slow to fast speed. All data logs write on USB uart changes.
static int8_t duty_cnt = 1;
static int8_t duty_inc = 1;
float duty = 0;
log_printf( &logger, " Clockwise \r\n" );
log_printf( &logger, "-----------------------\r\n" );
while ( duty_cnt < 10 ) {
duty = duty_cnt / 10.0;
Delay_ms ( 500 );
duty_cnt += duty_inc;
}
log_printf( &logger, " Brake \r\n" );
log_printf( &logger, "-----------------------\r\n" );
duty_cnt = 1;
Delay_ms ( 1000 );
log_printf( &logger, " Counterclockwise \r\n" );
log_printf( &logger, "-----------------------\r\n" );
while ( duty_cnt < 10 ) {
duty = duty_cnt / 10.0;
Delay_ms ( 500 );
duty_cnt += duty_inc;
}
log_printf( &logger, " Brake \r\n" );
log_printf( &logger, "-----------------------\r\n" );
duty_cnt = 1;
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
}
#define HBRIDGE6_DIRECTION_BRAKE
H-Bridge 6 Direction.
Definition hbridge6.h:115
#define HBRIDGE6_DIRECTION_COUNTERCLOCKWISE
Definition hbridge6.h:117
#define HBRIDGE6_DIRECTION_CLOCKWISE
Definition hbridge6.h:116
err_t hbridge6_set_duty_cycle(hbridge6_t *ctx, float duty_cycle)
H-Bridge 6 sets PWM duty cycle.
err_t hbridge6_pwm_start(hbridge6_t *ctx)
H-Bridge 6 start PWM module.
err_t hbridge6_pwm_stop(hbridge6_t *ctx)
H-Bridge 6 stop PWM module.
void application_task(void)
Definition main.c:67
The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.
Other Mikroe Libraries used in the example:
- MikroSDK.Board
- MikroSDK.Log
- Click.HBridge6
Additional notes and informations
Depending on the development board you are using, you may need USB UART click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.